FAQ
Q.
How are NTC thermistors calibrated?
  • Schutzbauelemente
  • /
  • Sensoren und Sensorsysteme
  • >
  • Temperaturschutz
  • /
  • Temperatursensoren (NTC)
  • >
  • SMD-NTC-Thermistoren (Schutzbauelemente)
  • /
  • SMD-NTC-Thermistoren (Sensoren)


A. At TDK thermistors are submerged in 25°C, 50°C and 85°C silicon oil and left to sit there for around 10 minutes until stable, then measured with a multimeter.
When carrying out the measurements, we select a range of voltages where the applied current will not generate heat.