Surge Arresters
B88069X1623S102
|
|
Size
| Length(L) |
|
| Width(W) or Diameter(D) |
|
| Height |
|
Electrical Characteristics
| DC Sparkover Voltage (Nom.) |
|
| Tolerance of DC Sparkover Voltage |
|
| Impulse Sparkover Voltage (Max.) [100V/µs] |
|
| Impulse Sparkover Voltage (Max.) [1kV/µs] |
|
| Impulse Sparkover Voltage (Max.) [5kV/µs] |
|
| Nominal Alternating Discharge Current |
|
| Nominal Impulse Discharge Current |
|
| Insulation Resistance (Min.) |
|
| Service Life: 1 operation 50Hz, 0.18s [9 cycles] |
|
| Service Life: 1 operation [8/20µs] |
|
| Service Life: 1 operation [10/350µs] |
|
| Service Life: 300 operations [10/1000µs] |
|
| Fail Safe (Short-circuit Spring) |
|
| DC Powerline |
|
| AC Powerline class III |
|
| AC Powerline class II |
|
| AC Powerline class I |
|
| Follow Current Capability |
|
| Temporary Over Voltage Capability |
|
| Number of poles |
|
| Glow Voltage |
|
| Glow to Arc Transition Current |
|
| Arc Voltage [1A] |
|
| Capacitance [1MHz] |
|
Other
| Climate Category [IEC 600068-1] |
|
| UL Certificate UL497B |
|
| UL Certificate UL1449 |
|
| Mounting Method |
|
| Soldering Method |
|
| Packaging |
|
| Package Quantity |
|
| Weight |
|
Tech Info
Documents
-
Cautions and Warnings
-
Quality
-
Environment Protection
-
Taping and Packing
-
Mounting Instructions
-
RoHS and SVHC/REACH Declaration
-
Material Data Sheets
-
EPCOS Publications
-
Construction
-
General Information/Definitions/Measuring Conditions for Telecom
-
Designation System for Telecom Types
-
Notes for Applications with Follow Current
-
Introduction
-
Overvoltage Protection of AC Power Lines
-
Overvoltage Protection of DC Power Lines
-
Overview of Types for Telecom
-
[Application Note] How to Use ESD/surge Protection Devices : Surge ArrestersHot
Technical Support Tools
Customer who viewed this product also viewed
Chip Beads
MPZ2012S300ATD25
|Z|=30Ω at 100MHz
Rated current=6A
L x W x T :
2mm x 1.25mm x 0.85mm
Leaded Disk Varistors
B72214S0301K101
Max. Operating Voltage [AC]=300Vrms
Max. Surge Current Imax(8/20μs,1time)=4500A
Surge Arresters
B88069X1623T502
2 electrodes Arresters
Nominal DC sparkover voltage = 700V
Surge Arresters
B88069X2033A802
2 electrodes Arresters
Nominal DC sparkover voltage = 2500V
Surge Arresters
B88069X2043B252
2 electrodes Arresters
Nominal DC sparkover voltage = 3000V
Surge Arresters
B88069X3563T502
2 electrodes Arresters
Nominal DC sparkover voltage = 800V
Surge Arresters
B88069X3820S102
2 electrodes Arresters
Nominal DC sparkover voltage = 1000V
Surge Arresters
B88069X6891T253
2 electrodes Arresters
Nominal DC sparkover voltage = 300V
Chip NTC Thermistors (Sensor)
B57421V2103J062
Resistance (at 25°C)=10kΩ
Resistance Tolerance (at 25°C)=±3%
TMR Angle Sensors
TAB4140-BAAB
Analog Output 3.0Vp-p (Single-end Sin+ / Sin- / Cos+ / Cos-, 5.0V applied)
TSSOP-16
Redundancy=Yes
+1 (Dual)
Angle Accuracy (Overall Temperature)=+/-0.6 deg