Surge Arresters

B88069X1913T902

Applications
General
Industrial
Type
S50-A90X
Status
ProductionProduction
Brand
EPCOS
  • Surge Arresters:s50-x_rab0353-x
  • Surge Arresters:s50-x

Images are for reference only and show example products.

Size

Length(L)
5.70mm Nom.
Width(W) or Diameter(D)
5.00mm Nom.
Height
5.00mm Max.

Electrical Characteristics

DC Sparkover Voltage (Nom.)  ?
90V
Tolerance of DC Sparkover Voltage
±20%
Impulse Sparkover Voltage (Max.) [100V/µs]  ?
550V
Impulse Sparkover Voltage (Max.) [1kV/µs]  ?
600V
Impulse Sparkover Voltage (Max.) [5kV/µs]  ?
Nominal Alternating Discharge Current  ?
5A
Nominal Impulse Discharge Current  ?
5kA
Insulation Resistance (Min.)  ?
1GΩ
Service Life: 1 operation 50Hz, 0.18s [9 cycles]
10A
Service Life: 1 operation [8/20µs]
10kA
Service Life: 1 operation [10/350µs]
500A
Service Life: 300 operations [10/1000µs]
100kA
Fail Safe (Short-circuit Spring)
NO
DC Powerline
NO
AC Powerline class III
NO
AC Powerline class II
NO
AC Powerline class I
NO
Follow Current Capability
NO
Temporary Over Voltage Capability
NO
Number of poles
2
Glow Voltage
60V
Glow to Arc Transition Current
0.8A
Arc Voltage [1A]
15V
Capacitance [1MHz]  ?
1pF

Other

Climate Category [IEC 600068-1]
40/125/21
UL Certificate UL497B
UL Certificate UL1449
Mounting Method
Surface Mount
Soldering Method
Reflow
Packaging
Axial Taping Reel
Package Quantity
900pcs
Weight
0.3g