Clamp AC Current Sensors

CCT354571-300-24-02

Applications
Industrial and InfrastructureIndustrial and Infrastructure
AC / DC
AC
Status
ProductionProduction
Brand
TDK
  • Clamp AC Current Sensors:CCT354571-300-24-02

Images are for reference only and show example products.

Size

Length(L)
39.50mm Max.
Width(W)
48.50mm Max.
Height(H)
72.00mm Max.
Internal Clamp Diameter
24.00mm Nom.
Detail Size Information
Please refer to the catalog

Electrical Characteristics

Applicable Current [50/60Hz]
0.1 to 300Arms
Nominal Current Transformation Ratio
3000:1
Output Current Accuracy
100mA ±1mA
Phase Difference
0.7° ±0.5°
Secondary Winding Resistance
103Ω
Open-circuit Protection
7.5V clamp element
Withstanding Voltage [1min.]
2.2kVAC
Insulation Resistance [DC500V]
100MΩ Min.

Other

Output Connector (Receptacle Housing)
PALR-02VF (JST)
Adaptable Connector (Plug Housing)
PAP-02V-S (JST)
Output Lead Wire
AWG22 140mm
Flame Retardant Grade
UL 94 V-0
Operating Temp. Range
-20 to 60°C
Packing
Bulk (Polystyrene form)
Package Quantity
24pcs
Weight
221g
Collapse All Expand All

Documents